E24™ 3.0 CARD | QUICK START GUIDE
EZLOGIC® CONTROLLER CONNECTOR
(CONECTOR DEL CONTROLADOR EZLOGIC)
DC (-)
(CORRIENTE DIRECTA DC (-)
+24V DC INPUT
(ENTRADA DE CORRIENTE DIRECTA +24V DC)
MOTOR RUNNING OUTPUT
(SALIDA DE MOTOR EN FUNCIONAMIENTO)
ANALOG SPEED INPUT
(SALIDA DE VELOCIDAD ANALÓGICA)
MOTOR DIRECTION
(DIRECCION DEL MOTOR)
MOTOR RUN
(ARRANQUE DEL MOTOR)
MOTOR CONNNECTOR
(CONECTOR DEL MOTOR)
MOTOR CABLE
(CABLE DEL MOTOR)
RED L.E.D. (FAULT)
[INDICADOR LED ROJO (FALLA)]
GREEN L.E.D.
(POWER CONNECTED)
INDICADOR LED VERDE (POTENCIA CONECTADA)
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
ON
(PRENDIDO)
RED L.E.D. (FUSE)
[INDICADOR LED ROJO (FUSIBLE)]
DC (-)
(CORRIENTE DIRECTA DC (-)
SW1-1
SW1-2
SW1-3
AMBER L.E.D. (INIDCATES CURRENT LIMITING)
[INDICADOR LED NARANJA (INDICA CORRIENTE LIMITADA)]
Question and Answer IconNeed help?

Do you have a question about the HYTROL E24 3.0 CARD and is the answer not in the manual?

HYTROL E24 3.0 CARD Specifications

General IconGeneral
CategoryControl Unit
Voltage24V DC
ModelE24 3.0
Current Rating3.0A
ProtectionOverload Protection

Summary

Motor Connection Header

DC Power Input Header

Optional Input-Output (I/O) Connection Header

M8 Connector for EZLogic®

Mounting Plate/Heat Sink

Configuration Switches

Current Limit Selection

Configures the control for low or high current limit mode based on motor selection.

Motor Speed Selection

Determines operating speed by setting multiple switches, matching speeds in different zones.

Motor Type Selection

Selects the motor type, influencing speed and current limit settings.

Feedback LED Indicators

Red Fuse LED

Indicates a blown 15 amp fuse, requiring board return for analysis or repair.

Red Fault LED

Signals various faults like hardware problems, voltage issues, or motor cable connection issues.

Amber Motor Current Limiting LED

Indicates motor overheating, power limiting, or operation at maximum allowed current.

Green Power LED

Confirms that power is properly applied to the control board.

Cover

Mount the Control

Select a Motor

Motor Selection (SW2-5)

Selects the motor type (100W24 or 125W24) for optimal performance.

Current Limit (SW1-3)

Sets the current limit mode (Low or High) based on the selected motor.

Select a Speed

Speed Settings (SW2-1 to SW2-4)

Configures operating speed using four switches to match multiple zones.

Analog Speed Input (0-10VDC)

Allows dynamic speed adjustment via a 0-10VDC input, overriding switch settings.

Select the Braking Action

Select the Rotation

Connect User I/O (Optional)

PNP Run Input

Activates the motor when active, OR'ed with Hytrol EZLogic® input.

PNP Reverse Input

Controls motor direction when active, alongside the run input.

PNP Running Output

Indicates when the motor is running, regardless of reverse input.

Analog +(0-10VDC) Input

Overrides speed settings dynamically based on input voltage.

DC Ground

Common ground point for referencing DC ground connections.