19
Software Control through
PC(communication port)
RS232 (matching) or LAN(optional)
Protection
Input Low Voltage Protection
Check the input characteristics
Input Overvoltage Protection
Check the input characteristics
Input Polarity Reversal Protection
yes
Output Overvoltage Protection
Check the output characteristics
Output Polarity Reversal Protection
yes
Short-circuit Protection
Recover after eliminating the Short-circuit fault,
no problem for long term Short-circuit
Temperature Protection
95
Temperature protection
Above 85
,decrease the output power, decrease
3A per degree.
Other Parameters
Noise
≤40dB
Thermal methods
Forced air cooling, fan speed rate regulated by
temperature, when inner temperature is too low,
fan runs slowly or stops; when controller stops
working, fan also stops running
Components
World brand raw materials. Compliance with EU
standards. All rated temperature of electrolytic
capacitors not less than 105
Smell
No peculiar smell and toxic substances.
Environment Protection
Meet the 2002/95/EC,no cadmium hydride and
fluoride
Physical
Measurement DxWxH (mm)
270*185*90
N.G(kg)
3
G.N(kg)
3.6
Color
Blue/Green (optional)
Safety
CE, RoHS, PSE,FCC
EMC
EN61000
Type of Mechanical Protection
IP21
Environment
Humidity
0~90%RH ( no condense)
Altitude
0~3000m
Operating Temperature
-20
~ +40
Storage Temperature
-40 ~ +75
Atmospheric Pressure
70~106kPa