The fuse on a unit repeatedly blows
Are you fitting right rating/type of fuse into unit?
Contact I-pix for more specific help with your problem, there may be an internal fault in the unit.
If you have the technical knowledge/skills you could look inside the unit and check the internal wiring for a lose
connections/shorts and also the power supply is working with a 15v output when
there is no load connected to it.
Dmx trouble shooting
The obvious
It is good practice to connect data line and terminate before switching on device.
Is the dmx line fitted to a buffer and data is being received
Is the dmx data line fitted with a line termination?
Does the units dmx mode set-up match the personality/ profile for the console provided?
Note: the LCD screen flashes intermittently when no data is present
TROUBLE SHOOTING
BB4 USERS MANUAL - PAGE 27