MESSAGE LIBRARY
Refer to BBP-5 Instal Guide for information on input triggers.
The same message may be linked to more than one trigger.
ABBREVIATED VERSION DISPLAYED IN
SELECTION SCREEN
MESSAGE DISPLAYED ON SCREEN AFTER
TRIGGER IS ACTIVATED
<Blank>
SERVICER
(Default Custom Message)
SERVICE
REQUIRED
DoorOpen
Door
Open
VentMode
Vent
Mode
RemoteOf
Remote
Off
RemoteSh
Remote
Shutdown
CleanFil
Clean
Filters
ServiceR
Service
Required
NoWaterF
No Water
Flow
FanOverl
Fan
Overload
FireShut
Fire
Shutdown
ACPlantF
AC Plant
Fault
HPFault
HP
Fault
LPFault
LP
Fault
HP/LPFau
HP/LP
Fault
S1OpenCi
(Default Forced Vent Input Message)
S1 Open
Circuit
S1Closed
(Default Remote On/Off Input Message)
S1Closed
Circuit
S2Closed
(Default System Fault Input Message)
S2Closed
Circuit
Designed and Manufactured in Australia by:
Innovative Air Systems Pty Ltd.
Unit 1 / 49 Miller Street
Murarrie, Queensland, 4172.
National Sales
Ph: 1300 306 125
sales@ias.net.au
Product Support
Freecall: 1800 354 434
support@ias.net.au
Touchpad User Guide
(Model: C-LCD-122-TL)
Question and Answer IconNeed help?

Do you have a question about the IAS C-LCD-122-TL and is the answer not in the manual?

IAS C-LCD-122-TL Specifications

General IconGeneral
Touch TechnologyResistive
Brightness250 cd/m²
Contrast Ratio500:1
Resolution800 x 600
InterfaceUSB
Operating System CompatibilityWindows
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 60°C

Summary

Default Display Screen

The Clock Display Screen

Details about the clock display screen and how to access it for time-related configurations.

Installation and Commissioning

Touchpad Dipswitch Configurations

Explains how to set touchpad dipswitches for compatibility with different Blackbox relay modules.

C-LCD-122-TL Connection Diagram

Illustrates the wiring connections for the C-LCD-122-TL touchpad and Blackbox relay module.

Quick Start Options

Standard Menu Options

To Change the Mode

Procedure for selecting the operating mode of the A/C system (Cool, Heat, Vent, Auto).

To Set the Fan Speed

Instructions for manually selecting fan speed or setting the fan to Auto mode.

To Change the HeatFan Setting

Configuration for indoor fan operation during heating mode (Contin or Auto/Cyc).

To Set the Run Timer

Setting the duration for the system to run when manually activated via the On/Off button.

To Edit the Setback Temperatures

Adjusting preset temperature limits for maintaining conditions within specific boundaries.

Clock Menu Options

To Set the Clock

Step-by-step guide to setting the Hour, Minutes, Day, Month, and Year values.

To Edit the Timeclock Programs

Procedure for setting start/stop times and defining active days for programmed schedules.

To Set Holidays

Instructions for programming holiday periods to override normal timeclock operation.

To Set Daylight Savings

Configuration to automatically adjust the clock for daylight saving time changes.

To Edit the System Settings

To Change the Compressor Delays

Setting the minimum on/off times for the compressor to prevent short cycling.

To Set the Deadband

Creating separate heating and cooling setpoints based on the deadband value.

To Set the Control Band

Adjusting stage separation and switching differential for heating and cooling.

To Edit the Service Timer

Configuring the system's run time monitor and associated service message.

To Select the Forced Vent Input Message

Choosing the message displayed for the forced vent input trigger.

To Select the Remote On/Off Input Message

Selecting the message shown for the remote on/off input trigger.

To Select the System Fault Message

Assigning a message for the system fault input trigger (S2 closed circuit).

To Select the Service Timer Message

Selecting the specific message to be displayed when the service timer activates.

To Edit the Custom Message

Creating and inputting a user-defined custom message for system alerts.