IBERITAL DE RECAMBIOS, S.A.
Page 14 of 22 manual electr.ce ingles 22-11-2004.doc
Programming the 3rd relay as safety device (auto fill up).
Programming the 3
rd
relay in the right touch path, you will have a new safety protection for
the heating element: when there is no water covering the probe, there is no signal coming to
the display nor from the display to the heating element. At the same time, if there is no water
covering the probe for more than 45 seconds, automatically the signal to the display will be
cut and from the display to the heating element too. All this process avoids working the
heating element without water.
In order to program this safety device:
1) Turn Off (position 0) the On-Off switch
2) Press the 1 long coffee, the hot water button and turn On (position 2) the On-Off
switch at the same time.
3) The Leds of the 1 long coffee and 2 short coffees will light.
4) Stop pressing the buttons and turn Off (position 0) the On-Off switch.
5) Turn On (position 2) the On-Off switch.
In case there would be no esternal push button (hot water button): turn the On-Off switch to
the Off position (Position 0), and set a link in the left side touch path. Then, turn the On-Off
switch to position 1 or 2.