Diagnostic Action
Smudged
l.
Check ribbon cartridge.
Printing
-
Jammed
-
Seated improperly
-
Excessive ink
-
Oily
or
dirty
Replace cartridge
if
damaged.
2.
Check for dirty, oily,
or
damaged platen.
Replace Print Mechanism
if
platen is
damaged. (See Section 3, "Removal/
Replacement.
")
3.
Check for dirty print head and print wires.
Clean
if
dirty.
4.
Check for dirty
or
bent ribbon shield.
Replace shield
if
damaged. (See Section 3,
"Removal/Replacement.")
5.
Visually check for worn
or
broken
ribbon drive gears. Replace Carriage Drive
assembly
if
damaged. (See Section 3,
"Removal/Replacement.
")
Uneven
1.
No adjustment can be made. Replace Print
Printing
Mechanism assembly. (See Section 3,
"Removal/Replacement.
")