Find the symptom in the following table; then follow the instructions given in the Action
column.
Symptom Action
Power Problems
The primary I/O drawer does not become powered on, no
OK prompt.
Go to “Map 1521: Cannot Power On The Primary I/O
Drawer, Operator Panel Does Not Show OK Prompt” on
page 91.
The CEC drawer does not become powered on. Go to “Map 1522: Cannot Power On The CEC Drawer”
on page 97.
The secondary I/O drawer does not become powered on,
no power present LED.
Go to “Map 1523: Cannot Power On The Secondary I/O
Drawer, Operator Panel Power Present LED Does Not
Come On” on page 104.
You have been directed here by the SPCN Error Codes
table and the error code is 1011 1C0
x
Go to “Map 1524: The SPCN Error Codes Table Directed
You Here and the Error Code is 1011 1C0x” on page 109.
90 Service Guide

Table of Contents