Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 1622 CEC regulator 2 non-power fault 1. Processor card
Location: U1.1-P1-C1
2. Primary I/O backplane
Location: U0.1-P1
1011 1623 CEC regulator 2 domain fault Processor card
Location: U1.1-P1-C1
1011 1910 Power supply 1 power source failure 1. Check input power to the
power supply
2. CEC drawer power supply 1
Location: U1.1-V1
3. Primary I/O backplane
Location: U0.1-P1
1011 1911 Power supply 1 fault 1. CEC drawer power supply 1
Location: U1.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1912 Power supply 1 non-power fault 1. CEC drawer power supply 1
Location: U1.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1913 Power supply 1 domain fault 1. CEC drawer power supply 1
Location: U1.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1914 Power supply 1 cooling fault 1. CEC drawer power supply 1
Location: U1.1-V1
2. CEC drawer fan controller card
Location: U1.1-X2
3. Primary I/O backplane
Location: U0.1-P1
1011 1916 Swapped power supply and cooling unit,
or missing power supply 1
1. Verify correct installation of
power supply or cooling unit
2. CEC drawer power supply 1
Location: U1.1-V1
1011 1920 Power supply 2 power source failure 1. Check input power to the
power supply
2. CEC drawer power supply 2
Location: U1.1-V2
3. Primary I/O backplane
Location: U0.1-P1
1011 1921 Power supply 2 fault 1. CEC drawer power supply 2
Location: U1.1-V2
2. Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
171