Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1021 7661 Missing fan 6 in power supply 2 I/O drawer power supply 2
Location: U0.2-V2
1021 7690 Slow secondary I/O drawer fan 9 in
cooling unit
1. Fan 9 (cooling unit)
Location: U0.2-F9
2. Secondary fan controller
Location U0.2-X2
3. Power distribution card
Location U0.2-X1
1021 7691 Missing secondary I/O drawer fan 9 in
cooling unit
Fan 9 (cooling unit)
Location: U0.2-F9
1021 8400 VPD configuration problem
1. Check for system firmware
update.
2. Call service support.
1021 8401 VPD access problem
1. Check for system firmware
update.
2. Call service support.
1021 840A VPD +5 stuck high Secondary I/O backplane
Location: U0.2-P1
1021 840B VPD +5 stuck low Secondary I/O backplane
Location: U0.2-P1
1021 840D I/O type mismatch 1. Check cabling
2. Set the I/O type to 85. See
Power Control Network Utilities
Menu on page 389.
3. Primary I/O backplane
Location: U0.1-P1
1021 840E SPCN default configuration loaded User error
1021 840F I/O type not recognized 1. Check cabling
2. Set the I/O type to 85. See
Power Control Network Utilities
Menu on page 389.
3. Primary I/O backplane
Location: U0.1-P1
1021 8A00 A different I/O drawer is connected to the
CEC
Informational only
1021 9012 Invalid address 1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.2-P1
1021 9013 Invalid address 1. Check SPCN cabling
2. Secondary I/O backplane
Location: U0.2-P1
1021 9014 Invalid address mode Update system firmware
Note: Allow up to 30 minutes for
update to take effect
Chapter 5. Error Code to FRU Index
187