Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1021 9021 SPCN temporary internal error Information message
1021 9022 Secondary I/O drawer not present Check cabling
1021 9023 Secondary I/O drawer present but off Information message
1021 902D Secondary I/O drawer not present Information message
1021 9038 Node fault Secondary I/O backplane
Location: U0.2-P1
1021 9039 Node fault Secondary I/O backplane
Location: U0.2-P1
1021 9042 EPROM Failure Secondary I/O backplane
Location: U0.2-P1
1021 9043 Download failure
1. Check for system firmware
update.
2. Call service support.
1021 9046 QDS packet sequence error
1. Check for system firmware
update.
2. Call service support.
1021 9047 QDS block sequence error
1. Check for system firmware
update.
2. Call service support.
1021 9080 Undefined status code received Secondary I/O backplane
Location: U0.2-P1
1021 90F0 Drawer not present in configuration table 1. Check SPCN cabling
2. Reset system, then reboot
3. Secondary I/O backplane
Location: U0.2-P1
1021 90F1 Drawer added to configuration table Information message
1021 9102 Permanent address assignment failed Secondary I/O backplane
Location: U0.2-P1
1021 9109 Download failure Secondary I/O backplane
Location: U0.2-P1
1021 9113 Firmware image corrupted Secondary I/O backplane
Location: U0.2-P1
1021 9114 Firmware image corrupted Secondary I/O backplane
Location: U0.2-P1
1021 9116 SPCN communication with operator panel
failure
1. Secondary I/O operator panel
Location: U0.2-L1
2. Secondary I/O backplane
Location: U0.2-P1
188 Service Guide