Table 5. Firmware Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
2602 0007 Failed to allocate bus resources to
PCI adapter
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update
available.
6. Replace primary I/O backplane
Location: U0.1-P1
2680 0Axy MX-PCI bridge BIST Failure The problem is associated with
bridge y in I/O drawer x.
Replace I/O backplane in I/O drawer
x. Location: U0.x-P1
See “AIX and Physical Location Code
Tables” in Chapter 1 for location
codes.
2680 0Cxx Machine check occurred 1. Replace the part identified by the
location code associated with this
error code.
2. If the location code associated
with this error code identifies an
adapter, and replacing the
adapter does not correct the
problem, replace primary I/O
backplane
Location: U0.1-P1