Operational Status
ENABLED The device is enabled for normal operation. For
multi-port devices this means that at least one
port is enabled.
ENABLED PENDING Waiting for completion of Enable request.
See Note The device is in a special state that is explained
on the Page.
DISABLED The device is Disabled. Diagnostic testing can
now be performed. For multi-port Devices this
means that all ports are disabled.
DISABLE PENDING Waiting for completion of Disable request.
DIAGNOSTICS A configured device is being used by the
diagnostics.
NOT CONFIGURED The device is not configured for normal
operation.
MIS CONFIGURED The configuration does not match the physical
device.
HARDWARE ERROR A hardware error has been detected that
prevents further use of the device.
Diagnostic Status
INACTIVE Diagnostic for the device is not running.
TESTING A testing process for the device is active and
the device is being tested.
LOOP AND LOG A testing process for the device is active and
will loop and log any errors until stopped.
LOOP UNTIL ERROR A testing process for the device is active and
will loop until an error occurs or it is stopped.
MESSAGE A testing process for the device is active and it
is waiting for user input.
Fault Status
OK The last test of the device completed without
error.
ISOLATED A hardware failure has been detected and
isolated to the device.
NON-ISOLATED A problem has been detected, but the failure
may be external to the device. This most often
occurs with network adapters that have external
cables, modems, or LAN connections. Running
a diagnostic of the adapter with a wrap plug
attached can usually determine if the adapter
has failed.
5-46 3746-9X0: MAE Installation and Maintenance