Table 2-1 (Page 18 of 25). POST and Diagnostics and Utilities Index
for Symptoms, Messages, Error Codes, or Beeps
Symptoms, Messages, Error
Codes, or Beeps
Action/FRU
Error Codes
10X - System board error or
continuous beep.
System Board
110 - System board parity error. “Memory” on page 2-38.
Set memory installed in Setup Utility for
non-parity SIMMs.
SIMMs
System Board
111 - I/O channel parity error. “Memory” on page 2-38.
I/O channel memory
Riser Card
System Board
114 - External ROM checksum
error.
“Diagnostics for Factory-Installed Riser
Card, Sound Card, or Adapter Cards Not
Supported by Diagnostics and Utilities CD”
on page 2-52.
Adapter Card
Riser Card
System Board
12X - Processor error. Run the Setup Utility; see “POST Error
Codes” on page 2-3.
Processor
System Board
13X - System board error. Run the Setup Utility; see “POST Error
Codes” on page 2-3.
Processor
System Board
161 - Low CMOS battery. CMOS clock/battery (if less than 2.8 V dc)
Run the Setup Utility; see “POST Error
Codes” on page 2-3.
System Board
162 - CMOS RAM error. CMOS clock/battery (if less than 2.8 V dc)
Run the Setup Utility; see “POST Error
Codes” on page 2-3.
System Board
Check Procedures 2-27