Check Procedures 2-17
Table 2- 2 Error Symptoms List
Error Symptoms Action/FRU
System han
g
s after
system boot.
Execute the Dia
g
nostic/All Test in PC-DR
dia
g
nostic pro
g
ram and set its
confi
g
uration at “Halt on Error” to see what
its potential problem cause might be.
"Undetermined Problem" on page 2-45.
Blinkin
g
cursor only, and
machine not workin
g
normally.
"Factory-Installed Drive Devices" on
page 2-24.
Diskette/hard disk drive
connection/cables
Diskette/hard disk drives
System board
Diskette Drive
Note: Ensure diskette drive confi
g
uration is set correctly in BIOS
Setup and its read/write head is clean before the any dia
g
nose of
diskette problems.
3.5-in. diskette drive does
not work.
Diskette drive power
Diskette drive connection/cable
Diskette drive
System board
Diskette drive read or
write error.
Ensure the diskette drive is not set to
[Write protect] in the Security
Options of BIOS Setup.
Diskette
Diskette drive cable
Diskette drive
System board
Diskette drive read/write
test error.
Diskette
Diskette drive cable
Diskette drive
System board