7031-D24 24 24 24
7031-T24 24 24 24
7214-1U2 1 1 6
7314-G30 8 8 8
I/O drawers are connected to the adapters in the CEC with the following cables:
Data transfer cables:
12X DDR cables for the feature 5802 and 5877 I/O drawers
12X SDR or DDR cables for the feature 5796 and 7314-G30 I/O drawers
Power control cables
12X I/O drawer cable connections are always made in loops to help protect against
a single point-of-failure resulting from an open, missing, or disconnected cable. A
system with nonlooped configurations could experience degraded performance and
serviceability. If a nonloop connection is detected, a problem is reported.
The first 12X I/O drawer attached in any I/O drawer loop requires two data transfer
cables. Each additional drawer in the loop (up to the maximum allowed) requires
one additional data transfer cable.
The first 12X I/O drawer attached to a system unit requires two power control
cables. Each additional I/O drawer added to a system requires one additional power
control cable. Each system has one power control loop. All I/O drawers attached to
a system are included in the same power control loop. Power control cable loops are
different in this regard from data transfer cable loops.
Dual-Port 12X Adapter Options
Dual-Port 12X Channel Attach Adapter (#6446): Use the short run adapter for
feature 5796 or 7314-G30 expansion I/O drawers located in close proximity to the
host system or to other drawers in the I/O expansion loop. This adapter does not
include signal repeaters.
Dual-Port 12X Channel Attach Adapter (#6457): Use the long run adapter for
feature 5796 or 7314-G30 expansion I/O drawers located farther from the host
system or other I/O drawers in the I/O expansion loop. This adapter includes signal
repeaters to accommodate the longer cable lengths.
12X Cable Choice
Each feature 5796 or 7314-G30 12X drawer requires one Dual-Port 12X Channel
Adapter, either Short Run (#6446) or Long Run (#6457). The choice of adapters is
dependent on the distance to the next 12X Channel connection in the loop, either to
another I/O drawer or the system unit. The following table identifies the supported
cable lengths for each 12X Channel adapter. I/O drawers containing the Short Run
adapter can be mixed in a single loop with I/O drawers containing the Long Run
adapter. In this table, a "Yes" indicates that the 12X cable identified in that column
can be used to connect the drawer configuration identified to the left. A "No" means
it cannot be used. The 12X DDR or SDR cables can be used with the feature 5796 or
7314-G30.
12X Cable Options
0.6 M 1.5 M 3.0 M 8.0 M
(#1829)(1)(#1830)(1)(#1840)(2) (#1834)(3)
12X DDR (#1861)(1)(#1862)(1)(#1865)(2) (#1864)(3)
5796 to 5796 w/12X
Short Run adapter
(#6446) in both
drawers Yes Yes No No
5796 w/ 12X Short
Run adapter (#6446)

Other manuals for IBM Power 750 Express

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power 750 Express and is the answer not in the manual?

IBM Power 750 Express Specifications

General IconGeneral
BrandIBM
ModelPower 750 Express
CategoryServer
LanguageEnglish

Related product manuals