IBM System x3100 M5 Product Guide 23
Electrical:
430 watt power supply:
100 - 127 (nominal) V ac; 50 - 60 Hz; 6.0 A (maximum)
200 - 240 (nominal) V ac; 50 - 60 Hz; 3.0 A (maximum)
Input kilovolt-amperes (kVA) (approximately)
Minimum configuration: 0.100 kVA
o
Maximum configuration: 0.506 kVA
o
350 watt power supply:
100 - 127 (nominal) V ac; 50 - 60 Hz; 7.0 A (maximum)
200 - 240 (nominal) V ac; 50 - 60 Hz; 3.5 A (maximum)
Input kilovolt-amperes:
Minimum configuration: 0.035 kVA
o
Maximum configuration: 0.350 kVA
o
300 watt power supply:
100 - 127 (nominal) V ac; 50 - 60 Hz; 7.0 A (maximum)
200 - 240 (nominal) V ac; 50 - 60 Hz; 3.5 A (maximum)
Input kilovolt-amperes:
Minimum configuration: 0.035 kVA
o
Maximum configuration: 0.350 kVA
o
Environmental data:
BTU output
Ship configuration: 341 Btu/hr (100 watts)
o
Full configuration: 1726 Btu/hr (506 watts)
o
Noise level
Models with fixed power supply: 4.2 bels (idle), 4.3 bels (operating)
o
Models with hot-swap power supply: 5.0 bels (idle), 5.1 bels (operating)
o