EasyManua.ls Logo

IBM System x3650 M5 - Page 597

IBM System x3650 M5
1010 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
806f060d-041dffff Array [ComputerSystemElementName] has failed. (Drive 29)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d041dffff or 0x806f060d041dffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
806f060d-041effff Array [ComputerSystemElementName] has failed. (Drive 30)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d041effff or 0x806f060d041effff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
806f060d-041dffff 806f060d-041effff
Appendix A. Integrated management module II (IMM2) error messages 581