1152 x 864 60 8, 16, 32
1024 x 768 60, 70, 75, 85 8, 16, 32
800 x 600 56, 60, 72, 75, 85 8, 16, 32
640 x 400 60, 72, 75, 85 8, 16, 32
Dimensions (1U rack drawer)
Width: 440 mm (17.32 in)
Depth: 559 mm (22.00 in)
Height: 43 mm (1.75 in)
Weight:
Minimum configuration: 11.0 kg (24.4 lb)
Maximum configuration: 12.7 kg (28 lb)
System x3250 M3 servers are intended for use as rack-drawer servers and are
tested and designed to operate in a horizontal position.
Standards
These systems support or comply with the following standards:
Hardware-enabled to meet the International Organization for Standardization
(ISO) 9241, Part 3
Equipment approvals and safety
Japan VCCI, Class A
Australia/New Zealand AS/NZS CISPR 22:2006, Class A
IEC-60950-1 (CB Certificate and CB Test Report)
Taiwan BSMI CNS 13438, Class A); CNS 14336
China CCC (China GB 4943-2001, GB 9254-2008 Class A, GB 17625.1:2003)
Korea KN22, Class A; KN24
Operating environment
Air temperature:
Server on
10.0 to 35.0 degrees C (50 to 95 degrees F); altitude: 0 to 914.4 m (3,000 ft)
10.0 to 32.0 degrees C (50 to 89.6 degrees F); altitude: 914.4 m (3,000 ft) to
2,133.6 m (7,000 ft)
Server off
10.0 to 43.0 degrees C (50 to 109.4 degrees F); maximum altitude: 2,133.6 m
(7,000 ft)
Shipping
-40 to 60 degrees C (-40 to 140 degrees F)
Relative humidity: 8% to 80%
Electrical
100 - 127 (nominal) V ac; 50 Hz - 60 Hz; 6.0 A
200 - 240 (nominal) V ac; 50 Hz - 60 Hz; 3.0 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.050 kVA
Maximum configuration: 0.550 kVA
Btu output: