Do you have a question about the IBP HDM97 Pocket Series and is the answer not in the manual?
Brand | IBP |
---|---|
Model | HDM97 Pocket Series |
Category | Measuring Instruments |
Language | English |
Information on IBP Medical GmbH, contact details, and website.
Log of document updates and changes made over time.
Lists the valid software revisions for the manual.
Important precautions regarding instrument usage, environment, and handling.
Describes how the HDM97Pocket can be equipped with up to 5 acquisition channels.
Formal statement that the product conforms to EU directives.
Guidelines for proper disposal and recycling of the instrument's battery.
Illustrates and describes the various inlets and connectors on the appliance part.
Describes the high accuracy option for pressure measurements.
Details the option for a dedicated conductivity probe connector.
Explains Conductivity, Temperature, Pressure, pH, Flow, and Timer channels.
Guidance on using the flow-through adapter for conductivity and temperature measurements.
Describes the primary functions assigned to each key on the keypad.
Details the usage of the yellow keys for menu navigation and value adjustment.
Instructions for turning the instrument on and performing a display self-test.
Explains the power saving function and how battery charge is displayed.
Discusses battery lifespan and the requirement for manufacturer-only replacement.
Explains how to adjust parameters like AUTO-OFF, BEEP, LANGUAGE, and CAL-RES.
Configuration options for the TIMER and Pressure Hold Test (PHT) functions.
Settings for enabling or disabling the Flow and pH measurement channels.
Settings for High Resolution, exiting menus, and saving configurations.
Procedures for measuring conductivity and temperature, including compensation.
Explains the principles behind temperature compensation for conductivity measurements.
Discusses why temperature coefficients are important for conductivity accuracy.
Explains how to choose between vendor-specific or adjustable temperature coefficients.
Step-by-step guide for editing temperature coefficient sets TC1 and TC2.
Instructions for performing temperature measurements and unit selection.
Procedure for zeroing the pressure transducer to compensate for drift.
Describes the four methods for temperature compensation during pH measurement.
Procedure for resetting the accumulated flow volume to zero.
Important warnings regarding adjustment and definitions of terms.
General procedure for invoking the instrument's adjustment menu.
Detailed steps for performing conductivity and pH adjustments.
Instructions for cleaning the instrument and its components.
Addresses issues like charging problems, power failures, and channel selection.
Specifies ranges, resolutions, and accuracies for conductivity and temperature.
Details specifications for pressure ranges, pH accuracy, and flow sensor performance.
Information on internal power, external supply, protection degree, and environmental limits.
Details the USB interface and the necessary driver installation process.
Guidance on using template projects and configuring hardware in IBPView.