Diagnostics and trouble shooting guide
Your game comes with extensive diagnostics to aid you in keeping your game running correctly.
To access the diagnostics, open the left lower door assembly.
Press the SELECTand DOWNbuttons at the same time in attract mode.
NOTE - GAME MUST BE IN ATTRACT MODE TO ENTER DIAGNOSTICS
In diagnostics, the Jumbotron will show the layout of the sensor boards.
It will light the location of the board in green when selected. You will notice the remainder of
the sensors are yellow. This indicates the remaining boards are sending and receiving
information. If you see any red, this would indicate the board in that location is not receiving
or sending information.
GREEN = Selected Sensor board.
YELLOW = Communication is established.
RED = No communication, check power or RJ45 for proper connections.
You will also notice the numbers under ID DIPS”. This indicates the proper dip switch setting
for this location. IT IS NOT READING THE DIPSWITCHES! It is only showing you the proper
settings for that location. White means it should be set to on while blue means it should be set
to off.
At the bottom of the screen, it will show you which RGB color the target should be. It will cycle
from Red to green to blue and repeat.
S1 and S2 have different meanings depending on which sensor you are testing.