Page 9
Volt/Amp, Frequency
Hz Switch (61-481 only)
Function
Range
Sensitivity Accuracy
400mV 40mV rms
4V 0.2V rms
40V 2V rms
400V 20V rms + (0.01% +5)
AC Voltage
750V 200V rms
40mA 20mA rms
400mA 20mA rms
AC Current
10A 2A rms
Temperature °C, Model 61-482 only
Temperature Accuracy
Overload
Protection
-20 ºC ~ 0 ºC ± (2% + 4 ºC)
1 ºC ~ 100 ºC ± (1% + 3 ºC) 600V rms
101 ºC ~ 500 ºC ± (2% + 3 ºC)
500 °C ~ 800 °C
± (3% + 2 ºC)
Temperature °F, Model 61-482 only
Temperature Accuracy
Overload
Protection
-4 ºF ~ 32 ºF ± (2% + 8 ºF)
33 °F ~ 212 °F ± (1% + 3 °F)
600V rms
213 ºF ~ 932 ºF ± (2% + 6 ºF)
933 º F ~ 1472 ºF ± (3% + 4 ºF)
Physical Characteristics
Characteristics Description
Dimensions (H x W x D)
183mm x 85mm x 33mm
202mm x 95mm x 46mm(with holster)
Weight (with battery) 0.4Kg
With holster 0.6Kg
Environmental Characteristics Description
Temperature operating 0 to + 50°C
Non-Operating -20 to + 60°C
Humidity (operating) < 80% R.H.
Altitude Operating 2,222 m (7290 ft.)
Non-Operating 12,300 m (40354 ft.)
Vibration & shock Operating
MIL-T-28800E TYPE II Class 5
2.66gRMS, 5 to 500 Hz, 3axes
(10 minutes each)
Dust / Water Protection IP Rating IP 64
Indoor Use
Form number TM61480-1-2 Rev 5 July 2002