ADVANCED CONTROLS ACCESS CONT'D
Press Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
N/A Do not Do not
adjust adjust 60
P A R A
1. 6 0
2. 0 1
CH System 00 = Off 01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
3. 0 1
DHW System 00 = Off 01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
CH ow temperature (
o
C) T1 (max.) 20 90 82
CH ow temperature (min) (
o
C)
Lowest set ow temperature on the warmest day (papa 12) 15 60 25
4. 8 2
. 2 0
1
2
3
4
P10 appears
for 1 second then
10
Minimum outside temperature (
o
C) -20 10 -05
Coldest outside temp. the system is designed to work against
11
P11
Maximum outside temperature (
o
C) 15 25 20
Warmest outside temp. the system is designed to work against
12
P12
Outside temperature (
o
C) -30 10 -02
(at which frost protection starts)
13
P13
Steps 5 to 9 are not accessible.
Outside temperature correction (
o
C) -05 05 00
(for boiler reading of outside temperature)
14
P14
N/A 20 45 40
15
P15
N/A 10 40 20
16
P16
N/A 01 30 03
17
P17
Blocking CH ow temperature (
o
C)
Boiler will not re if the CH ow temperature set point is less than this Do not Do not 25
note 00 = Off adjust adjust
. 2 5
P18
18
continued...........
. - 0 5
. 2 0
. - 0 2
. 0 0
. 8 0
. 2 5
. 1 0