o The accumulation of unburned pellets ensuing a failed ignition must be
removed before repeating ignition. Also check that they are fed correctly
and that the combustion air inlet/smoke outlet are regular.
If ignition fails repeatedly, immediately suspend use of the product and
contact a qualified technician to check its operation. Compliance with these
indications is absolutely sufficient to guarantee proper operation and to avoid
any type of problems with the product. If the above-mentioned precautions
are not taken, and during ignition the combustion pot is overloaded with
pellets thus generating anomalous smoke in the combustion chamber,
carefully follow the indications below:
o Do not disconnect electrical power to the product for any reason what ever:
this would stop the smoke extractor, releasing smoke into the environment.
o Take the precaution of opening the windows to ventilate the installation
room from any smoke in the environment (the chimney might not work
properly).
o Do not open the fire door: this would compromise regular operation of the
smoke extraction system to the chimney.
o Just switch the boiler off by acting on the on-off button on the control panel
(not the rear power supply socket button!) and move away until smoke has
completely evacuated.
Before attempting re-ignition, clean the combustion pot and its air passage holes
completely of all deposits and unburned pellets. Put the combustion pot back in
place, removing any residue from its support base. If ignition fails repeatedly,
immediately suspend use of the product and contact a qualified technician to
check its operation and the chimney.