Troubleshooting Draco tera IP Gateway
38
9 Troubleshooting
For more help in case of problems with the matrix, please refer to the Draco tera user manual.
9.1 IP Connection Failure
Diagnosis Possible reason Measure
No Matrix Grid
connection available.
The destination type is set to EXT Unit. Set the designation type to Grid.
The destination data is wrong. Check the designation IP address of both
IP Gateway boards.
Check the designation port of both IP
Gateway boards.
Check the designation MAC address of
both IP Gateway boards.
The IP Gateway assignment is only set in
one of two matrices.
Set the IP Gateway assignment in both
matrices.