Draco tera enterprise Configuration via OSD
91
Real Time Clock
Field Entry Description
Date* MM 1 to 12 Enter the month.
DD 1 to 31 Enter the day.
YY 1 to 99 Enter the year.
Day 1 to 7 Enter day of the week.
Time hh 0 to 23 Enter the hour.
mm 0 to 59 Enter the minute.
dd 0 to 59 Enter the second.
* Date format according to the English notation.
Configuring the Time Server
To configure a time server, proceed as follows:
1. Select Configuration > Date+Time in the main menu.
2. Set the SNTP Client option to Y (Yes).
3. Enter the IP address of your SNTP server into the SNTP Server field.
4. Select your time zone in the Time Zone field.
5. Click Okay to confirm your settings.
6. Restart the matrix.
The system time will now be provided by the SNTP server.
Configuring the Real Time Clock without Time Server
To set the real time clock without using SNTP, proceed as follows:
1. Select Configuration > Date+Time in the main menu.
2. Set the current date in the Date field.
3. Set the current Day in the Day field.
4. Set the current time in the Time field.
5. Click RTC to confirm your settings.
The real time clock is now provided.