For 15" (38.1 cm) model only:
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
For all models except 15" (38.1 cm) model:
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This cooktop is manufactured with a frame connected, green or
bare ground wire. Connect the cooktop cable to the junction box
through the UL listed or CSA approved conduit connector.
1. Disconnect power.
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. See "Electrical Connection Options Chart" to complete
installation for your type of electrical connection.
Electrical Connection Options Chart
For cooktops with a 4-wire cable:
If your home has: If your cooktop has: Go to Section:
4-wire 4-wire 4-Wire Cable
from Home
i Power Supply to
4-Wire Cable
(1_3cm) from Cooktop
4-Wire Cable
from Home
Power Supply to
3-Wire Cable
from Cooktop
For cooktops with a 3-wire cable:
3-wire 4-wire 3-Wire Cable
from Home
Power Supply to
4-Wire Cable
(1_3cm) from Cooktop
3-wire 3-Wire Cable
from Home
Power Supply to
3-Wire Cable
from Cooktop