1ǃMaintenance of fill valve
Troubleshooting
1.The water level too high or too low
malfunction
solve way
2.Can not stop water
3.Fill water speed slow
4.Others questions
Adjust the water level
Wash the rubber and seal and filter
Wash filter, increase the water pressure
Pleases consult with a professional technician
2ǃMaintenance for flush valve
malfunction
Troubleshooting
1.Can not flush water
reason
solve way
1.Leaking
The flush pole may be damaged Replace the flush pole
The working water level too low Adjust the working water level
The rubber seal can not seal water
The movement of flush valve is blocked
Replace the rubber seal
Wash the debris of flush valve
ķ$GMXVWWKHVPDOOIOXVKZDWer volume
by adjust the small flush adjuster.
ĸWash the debris out
by flushing and clean water.
sealed rubber
Ĺ7DNHRXWRIWKHVLlica gel of flush
valve,clean or replace it.
small flush adjuster
ĺ7DNHRXWRIWKHVHDOed rubber of
flush valve.clean or replace it.
ķTurn the knob,adjust water level height.
Take off the filter tip and clean Loosen the nut and clean or replace
the valve core and the silica gel of fill valve
ĸWash the dirt
valve core
silica gel