Troubleshooting:
----SondaTemp..corto.Avisenserv.tec.
The temperature probe has a short circuit.
----SondaTemp.defet.Avisenserv.tec.
The temperature probe give a value above the desired temperature so it means it is
breakdown.
----Desagüeobturado.Avisenserv.tec.
Thesystemitistryingtolluptheboile.Thedrainitiscolapsed,orthevalveofll
up or level probe it is damaged.
----Detectadaavería.Avisenserv.tec.
Contact with the after sales service.
----Alarmatemp.Avisenserv.tec.
For an excess of temperature the security thermostat has set off. It has to be norma-
lised after switching on again.
----Cald.nosellena.Avisenserv.tec.
During many time the system is trying to switch on and there is any change in the
levels:thereisnowatersupply,thellinvalveisdamage,thellupvalveisdamage,
thellinvalveitisopenorthelevelprobeisdamage.
----Norecibedatos.Avisenserv.tec.
The connection between the panel and the generator has some cable brokken or
disconnected.
----Ventil.apagada:Sistemaparado
The ventilation is switch off manually with the bath working during more than 15
minutes and it appears this message on the panel. It is enough with switch on again
the ventilation.
----Vent.Invertido.Avisenserv.tec.
the fan of the precipitate of direct current it is connected on the other way round, you
have to invert the polarity.
----Aguanoevapora.Avisenserv.tec.
The system has detected that after 20 minutes, there is no change in the levels. Le-
vel probe damage, Bath temperature higher than the temperature registered.