ENGLISH
26 SRKSMART115V_11-01-2018
K BASIC - K SMART - K ECOSMART 115V
There are two power supply plugs on the back of the Minibar.
Connect the “POWER” plug to the socket in the room specically for the Minibar (socket not connected
to the energy saving system).
Connect the “SIGNAL” plug to any socket connected to the energy saving system (Energy saver).
NOTE: The K Smart Minibar operates in STANDARD/TIMER mode where the “SIGNAL” plug is not con-
nected. Standard mode refers to operation not relative to identication of the Guest in the room and
operation which is regulated by the temperature selected by the Client using the switch described above.
Attention!
If the POWER and SIGNAL cables are connected in reverse, the fridge will operate whilst the guest is in
the room and will switch itself off when the guest leaves the room.
To conrm that the connection is correct, check that the light illuminates when opening the Minibar door
subsequent to checking that:
1) the energy saving system (Energy saver) is not functioning and that the smart card has not been inserted
2) the Minibar is on (the temperature switch at the front of the Minibar must not be in position “0”).
In the instance that the light does not illuminate, invert the connection of the two power cables.