EasyManua.ls Logo

Indel B K40 PLUS PV 115V - Wiring Connections and Earthing; Electrical Safety Guidelines

Indel B K40 PLUS PV 115V
77 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
SERIE K ECOSMART
SRKECOSMART-01_15-01-2014 23
WIRING CONNECTIONS AND EARTHING
Before putting the plug into the power socket, make sure the mains voltage is the same as the one shown
on the technical specication plate (located inside the Minibar) and that the socket is equipped with
proper earthing, as laid down in the regulations on wiring system safety. Also, the power socket must
be able to hold up to the maximum power of the device, shown on the same plate.
Attention please!
If the socket is not equipped with an earthing system or if multiple sockets or adaptors are used, the Ma-
nufacturer will not be liable for any injury or damage to things and/or to the Minibar.
Attention please!
The user must always be able to access the power supply socket.
Attention please!
If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualied person in order to avoid a hazard.
Attention please!
If you dispose the fridge, you must take off the front door.
There are two power supply plugs on the back of the Minibar.
Connect the “POWER” plug to the socket in the room specically for the Minibar (socket not connected
to the energy saving system).
Connect the “SIGNAL” plug to any socket connected to the energy saving system (Energy saver).
NOTE: The K Ecosmart Minibar operates in STANDARD/TIMER mode where the “SIGNAL” plug is not
connected. Standard mode refers to operation not relative to identication of the Guest in the room and
operation which is regulated by the temperature selected by the Client using the switch described above.
Attention!
If the POWER and SIGNAL cables are connected in reverse, the fridge will operate whilst the guest is in
the room and will switch itself off when the guest leaves the room.
To conrm that the connection is correct, check that the light illuminates when opening the Minibar door
subsequent to checking that:
1) the energy saving system (Energy saver) is not functioning and that the smart card has not been inserted
2) the Minibar is on (the temperature switch at the front of the Minibar must not be in position “0”).
In the instance that the light does not illuminate, invert the connection of the two power cables.