INSPECT
Inspect for shipping damage. If damaged or parts are missing, notify your
Absocold dealer at once.
INSTALLATION REQUIREMENTS
Remove all packing material and tape. Install on a level floor or well-
supported counter. Avoid any direct sunlight, heat source, or moisture.
This refrigerator is designed to be
freestanding
that is, the appliance is to
be installed at least 2” from the wall and the cabinet bottom is at least ¾to
1” above the floor or carpet, in order to let the air circulate freely around
the refrigerator.
ELECTRICAL REQUIREMENTS
115 volts, 60 Hz.
ELECTRICAL GROUNDING
(for 115-volt models only)
Must be grounded. Uses 110-115 volts, 60 Hz.
(60 cycles A.C.) Do not use extension cord. Use three-prong plug, with
three-prong grounded wall outlet.
Unless the above grounding method is followed, you are not protected
against severe or lethal shock, in the event of a short circuit of an electrical
component or wiring of refrigerator.
TO CONTROL TEMPERATURE
This function is not designed for guests, but only for hotel management.
Temperature control is adjustable through the 1/4" diameter hole in the
rear cover plate. With a Phillips screwdriver rotate counterclockwise for a
warmer setting, and clockwise for a colder setting. The refrigerator is
shipped at a medium setting for your convenience.
THINGS YOU OUGHT TO KNOW
WHEN THE
QUICK CHILL N SNOOZE
® REFRIGERATOR IS INSTALLED
ADVANCED FUNCTIONS*
Advanced functions that can provide
greater control over the refrigerators
operation:
SNOOZE® function
Turns compressor off for 8 hours.
1. Push the SNOOZE button once.
Red light appears when it is
activated.
2. The refrigerator will be off for 8 hours.
3. During this period, temperature of refrigerator will rise, but
once 8 hours have passed, it will start back up automatically.
4. To deactivate SNOOZE function, simply push SNOOZE
button again.
QUICK CHILL® function
Turns compressor on continuously for 2 hours.
1. Push the QUICK CHILL button once. A green light appears
when it is activated.
2. The refrigerators compressor will operate continually for 2
hours. After this period, the refrigerator will return to normal
operation. This function cools beverages faster than normal
operation.
3. To deactivate QUICK CHILL function, simply push
QUICK CHILL button again.
CAUTION
Should you unplug the refrigerator, allow at least three minutes before restarting in order to allow the start relay to function properly.
USE AND CARE INFORMATION
TIPS ON EVERYDAY USE AND CARE
DEFROST
: As far as temperature control is set at ordinary position, evaporator is automatically defrosted and no manual operation is
needed to defrost. Defrosted water is drained out to evaporating tray on the back of the refrigerator and is evaporated automatically.
FOR ALL CLEANING
: Mix 2 tablespoons baking soda with 1 quart warm water, or use mild soap. No strong cleaners, scouring powder or
pads should be used.
BEFORE CALLING FOR SERVICE
Check plug and fuse. Test outlet with lamp or other device. Check red SNOOZE light (located inside of refrigerator). If this light is on,
compressor is off for 8 hours. You can turn it on by pressing SNOOZE button one more time. When you call, refer the model number and
the problem to the Service Department at your nearest authorized Service Center or contact Absocold at (800) 843-3714 or (765)
935-7501.
DANGER—ELECTRICAL SHOCK HAZARD. Disconnect power before servicing.
WARNING!
This refrigerator should be connected directly to a grounded electrical wall outlet.
No extension cords, multi-connection bars, etc. should be used.
*Patent No.: US 7,634,918 B2