EasyManua.ls Logo

Infortrend EonStor DS 1012 - Maximum Concurrent Host LUN Connection (Nexus in SCSI)

Infortrend EonStor DS 1012
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
Maximum Concurrent Host LUN Connection (“Nexus” in SCSI)
The "Max Number of Concurrent Host-LUN Connection" menu option is used to set
the maximum number of concurrent host-LUN connections.
Maximum concurrent host LUN connection (nexus in SCSI) is the arrangement of the
controller internal resources for use with a number of the current host nexus.
For example, you can have four hosts (A, B, C, and D) and four host IDs/LUNs (IDs 0,
1, 2 and 3) in a configuration where:
Host A accesses ID 0 (one nexus).
Host B accesses ID 1 (one nexus).
Host C accesses ID 2 (one nexus).
Host D accesses ID 3 (one nexus).
These connections are all queued in the cache and are called four nexus.
If there is I/O in the cache with four different nexus, and another host I/O comes with
a nexus different than the four in the cache (for example, host A accesses ID 3), the
controller returns busy. This occurs with the concurrent active nexus; if the cache is
cleared, it accepts four different nexus again. Many I/O operations can be accessed
via the same nexus.

Table of Contents

Related product manuals