EasyManua.ls Logo

Infortrend EonStor DS 1012 - Configuration Rules

Infortrend EonStor DS 1012
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
81
Configuration Rules
Following are the rules for connecting SAS interfaces across RAID and JBOD
enclosures:
Fault-tolerant links in a dual-controller combinations: Corresponding to SAS
drives’ dual-ported interface, two physical links are available from each disk
drive, routed across the backplane board, each through a SAS expander,
and then interfaced through a 4x wide external SAS port.
With data paths through separate SAS domains, access to disk drives can
be continued in the event of a cable link or SAS JBOD controller failure.
Designation Description Designation Description
1
RAID controller A
5
Dual-ported SAS drives
2
RAID controller B
6
Expander
3
JBOD controller A
7
To another JBOD
4
JBOD controller B
Fault-tolerant Links to SAS disk Drives
SAS expansion cables will be available with the JBODs. Note that if many
JBODs are connected, a longer SAS external cable (e.g., a 120cm cable)
may be necessary for connecting a JBOD from the opposite direction

Table of Contents