EasyManua.ls Logo

Infortrend S12F-G1842 - Replacing the BBU

Infortrend S12F-G1842
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EonStor / EonStor DS S12/S16/S24 Series
157
Replacing the BBU
To replace the BBU, follow these steps:
1. Remove the controller out of the enclosure (refer to Removing the Controller
).
2. Loosen screws (1) and remove the BBU (2). For type II controller models, please
unplug the BBU power connector (indicated by the blue circle).
11
2
1
2
1
Type I controller systems Type II controller systems
3. the top cover, unscrew For type II controller systems, to separate the BBU from
the screws shown in the following illustration.
BBU
4. Install the replacement module and fasten screws (refer to Installing the BBU
).
5. Reinstall the controller (refer to Installing the RAID Controller
).
NOTE
A replacement BBU takes approximately twelve hours to charge to its full capacity.
The life expectancy of a BBU is three years.
If the cause of a failure cannot be determined even after a BBU module is
replaced, contact your system vendor.
151

Table of Contents

Related product manuals