EonStor / EonStor DS S12/S16/S24 Series
158
Replacing the FBM
To replace the FBM, follow these steps:
11
2
3
4
5
1.
Remove the controller module from the chassis (refer to Removing the
Controller).
2. Remove the section).
) of the top cover (3) from the
controller chassis.
4. Pull the retention latches (4) away from the FBM (5). Use your finger nails if the
FBM does not easily disengage. Once disengaged, the flash module will pop up.
You can then remove it from the socket.
5. Insert the replacement FBM into the socket at a 15 degree angle. When fully
inserted, press the flash module down until it is snapped by the retention latches.
6. Reinstall the BBU (refer to Installing the BBU
BBU module (see the previous
3. Remove the top screw (1) and side screw (2
) and the controller (refer to
Installing the RAID Controller
).
152