EonStor / EonStor DS S12/S16/S24 Series
166
Enclosure Replacement Must Knows
1. Always use the differential diagnosis method mentioned above to test the
integrity of the backplane board.
2. Record your differential diagnosis findings and consult with Technical Support.
osure replacement procedure!
3. If the system is still operable, you can choose to leave it running but remember to
fill up all module slots after swapping them around (empty module slots will
interrupt airflow).
4. As a faulty backplane board may affect the system in a variety of ways
(performance, stability, data integrity, etc.), once you have consulted Technical
Support staffs and confirmed it is indeed a new enclosure you need, you should
arrange for a replacement immediately!
5. Replacing an enclosure will incur significant amount of system downtime
so do confirm module integrity and consult Technical Support before going
ahead with the encl