EasyManua.ls Logo

Infortrend S12F-G1842 - Power Supply

Infortrend S12F-G1842
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EonStor / EonStor DS S12/S16/S24 Series
171
Power Supply
S12 and S16 Series
Dual controller model:
100VAC @ 10A
240VAC @ 5A with PFC (auto-switching)
Input Voltage
Single controller model:
100VAC @ 6A
240VAC @ 3A with PFC (auto-switching)
Frequency 47 to 63Hz
Dual controller model: 530W; idle: 345W; Busy: 367W
Power Consumption
Single controller model: 350W; idle: 261.9W; Busy: 284.8W
DC Output 12.0V: 28A (Max.)
5.0V: 43A (Max.)
Input Frequency 47 to 63Hz
AC Input 100VAC @ 10A or 240VAC @ 5A with PFC
Power Factor Correction Yes
Hold-up Time At least 16ms at 115/230VAC full load after a loss of AC input
I C Through backplane to controll
2
er
Over-temperat e
Protection
Auto shutdown when lost cooling or exceeded ambient temperature;
over-voltage protection is also
ur
available.
PSU specifications described above may not represent all models. For details,
please refer to specific model specifications
.
S12F-R/S2840N and S12S-J2000R/S-N DC PSU
Minimum Nominal Maximum Inrush current
Input Voltage Range (Vdc) -36V -48V -72V
Current 22A 16A 11A
25A @ 10ms
60A @ 1ms
DC Output
12.0V: 43A (Max.); 0A(Min.)
5.0V: 28A (Max.); 0A(Min.)
Note: Total DC output power must
not exceed 530W; 5V peak is 35A
and when reached, the sustained
peak duration must be kept within
60 seconds.
I
2
C Through backplane to controller
Over-temperature
Protection
Auto shutdown when lost cooling or exceeded ambient temperature;
over-voltage protection is also available.
174

Table of Contents

Related product manuals