EonStor / EonStor DS S12/S16/S24 Series
T
o install the MUX board and its support plate (go to step 2 if you are installing
a brand new system that is not yet in operation):
1. Identify the hard drive tray you would like to install the MUX board onto by starting up
your SANWatch Manager and go to Storage Manager > Information > Enclosure
View
The icons indicate the current status of each hard drive tray
Icons
The drive tray is filled with an available hard drive.
The drive tray is empty.
The drive is a spare drive
.
The drive tray does not exist or the hard drive is not
ready for operation due to testing or other reasons.
2. Remove the tray you wish to install the MUX board to, from the enclosure. Use a
flat-blade screwdriver to set the rotary bezel lock in the horizontal orientation.
57