EonStor / EonStor DS S12/S16/S24 Series
System mode
l numbers with a designated ā€œNā€ are powered by DC PSUs.
The kit is for DC PSU systems only and the earth lead kit MUST be installed before you power
on your system. The earth lead cable, dedicated screws and cage nut can be found in the
accessory box. It is recommended to install the earth lead kit once the enclosure has been
installed into the cabinet.
To install, attach one end of the earth lead cable to the enclosure and secure it with the
dedicated screw as shown in the illustration below:
Att
ach the other end of the earth lead cable to the
cabinet rack post with the dedicated screw. If your
cabinet rack post does not come with screw threads,
use the cage nut provided to secure it to the rack
post.