18
SECTION 5 — DISPLAY AND MENU OPERATION
Graphical LCP
The control panel is divided into four functional groups:
1. Graphical display with Status lines.
2. Menu keys and indicator lights - changing
parameters and switching between display
functions.
3. Navigation keys and indicator lights (LEDs).
4. Operation keys and indicator lights (LEDs).
All data is displayed in a graphical LCP display, which
can show up to five items of operating data while
displaying [Status].
Display lines:
a. Status line: Status messages displaying
icons and graphic.
b. Line 1-2: Operator data lines displaying data
defined or chosen by the user. By pressing the
[Status] key, up to one extra line can be added.
c. Status line: Status messages displaying text.
The LCD-Display
The LCD-display has back light and a total of 6 alpha-
numeric lines. The display lines show the direction of
rotation (arrow), the chosen Set-up as well as the
programming Set-up. The display is divided into 3
sections:
Top section: Displays up to 2 measurements in
normal operating status.
Middle section: The top line in the displays up to
5 measurements with related unit, regardless of
status (except in the case of alarm/warning).
Bottom section: This always displays the state
of the frequency converter in Status mode.