Back
Digital
IO
This
screen
allows
the
user
to
add,
edit
or
delete
Input
/
Output
devices.
Adding
Modules
Do
the
following
to
add
I/O
modules:
Select
Add
Module.1.
From
the
ADD
Device
IO
field,
select
a
device
type
from
the
drop
down
list:2.
QLight
(0x4)x
Light
Tree
(0x3)x
Socket
Tray
(4x4)x
DIO
Box
(4x4)x
DIO
Box
(8x8)x
From
the
Ports
Available
field,
select
a
port
to
establish
physical
connection.3.
NOTE
:
Make
sure
to
select
the
port
to
which
the
I/O
device
is
connected.
To
set
IO
Assignment,
do
as
follows:4.
If
QLight
(0x4)
or
Light
Tree(0x3)
is
selected
from
ADD
Device
IO
field,
select
IO
Assignment
to
view
Output
Assignment
contents.
a.
To
edit
the
Output
Assignment
contents,
select
Edit.x
For
point
0
-
3,
do
as
follows:
x
From
the
Behaviour
fields,
select
from
a
list
of
behaviours
and
then
select
Apply .
x
From
the
Polarity
fields,
select
from
the
following:x
Normally Openx
Normally
Closex
In
the
Timeout
(Sec.)
fields,
enter
the
duration
for
which
the
output
needs
to
be
active.
x
For
activating
LED
notification,
select
Blink.x
Select
Ok.x
If any other device is selected from ADD Device IO field, select IO Assignment to view b.