Back
Factory
Reset
This
screen
allows
the
user
to
restore
the
controller
memory
and
database
to
the
original
system
state. Any data stored on the controller memory and database will be erased, settings will be
restored
to
default
set
by
the
manufacturer.
Do
the
following
to
do
a
factory
reset:
NOTE :
It
is
recommended
to
make
backup
before
performing
factory
reset!!
Select
Factory
Reset .1.
At
the
confirm
prompt,
select
Yes.2.
On
completion,
a
success
or
failure
notification
will
be
displayed.
Factory
reset
operation
does
not
reset
IP
address
of
the
controller
to
default
values.
To
reset
IP
address of the controller to default values, press the IP Address Reset Pin (1) for 10 seconds.
Refer
to
Figure
A.
Figure
A:
View
of
IP
Address
Reset
Pin
on
fastening
controller
Once
reset,
the
default
values
for
Port
1
and
Port
2
are
as
follows:
Port
Default
Values
Por
t
1
IP
Address
-
192.168.5.5
Subnet
mask
-
255.255.255.