- 34 -
Quick setup
Set AI if AI is
frequency reference
F4-13 AI curve 1 minimum input 0.00 0.00
0 V to F4-15
F4-14
Corresponding setting of AI1 minimum
input
0.0 0.0
-100.0% to 100.0%
F4-15 AI1 maximum input 5.00
-
F4-13 to 10.00 V
F4-16
Corresponding setting of AI1 maximum
input
100.0
-
-100.0% to 100.0%
Set multi-reference
values
FC-01 Reference 1 100.0 100.00
0.0 to 100.0%.
NOTE: FC-01 is set as nominal speed of elevator.
FC-02 Reference 2 11.0 11.0
0.0 to 100.0%.
NOTE: FC-02 is set as creep speed of elevator.
FC-04 Reference 4 40.0 40.00
0.0 to 100.0%.
NOTE: FC-04 is set as inspection speed of elevator.
FC-08 UPS reference frequency 10.0 10.0
0.0 to 20.0%.
NOTE: FC-08 is set as UPS speed of elevator.
CONTINUE