- 36 -
Quick setup
Set DO function
F5-01 FM function selection 2 2 (Fault output)
0: No output
1: AC Drive running
2: Fault output
36: Software current limit exceeded
42: Brake output
43: MC (Magnetic contactor) output
Setting range: 0 to 59
NOTE: This signal goes to magnetic contactor.
F5-02 Relay function selection (TA/TB/TC) 43 43 (MC)
Setting range: same as FM
NOTE: This signal goes to magnetic controller.
F5-03 Relay function selection (PA/PB/PC) 42 42 (Brake)
Setting range: same as FM
NOTE: This signal goes to brake contactor.
Set magnetic
contactor
F8-60 Drive run delay ON set time 0.20 0.20
0.20 to 10.00s
NOTE: If MC is controlled by elevator controller, then F8-60 is useless.
F8-61 MC contactor delay OFF set time 0.20 0.20
0.00 to 10.00s
NOTE: If MC is controlled by elevator controller, then F8-61 is useless.
Set brake contactor
F8-55 Brake release current threshold 20 20
0 to 200%
F8-56 Brake release frequency threshold 0.20 0.20
0.00 to 25.00 Hz
F8-57 Brake release delay ON set time 0.0 0.0
0.0 to 5.0s
F8-58 Brake apply frequency threshold 0.5 0.5
0.00 to 25.00 Hz
F8-59 Brake apply delay OFF set time 0.2 0.2
0.0 to 5.0s
CONTINUE