- 37 -
Quick setup
Set acceleration and
deceleration
F0-17 Acceleration time 1 3.0 3.0
0.0 to 6500.0s
F0-18 Deceleration time 1 2.0 2.0
0.0 to 6500.0s
F8-04 Stop stage deceleration time 2.0 2.0
0.0 to 6500.0s
Set startup frequency
F6-03 Startup frequency 1.0 1.0
0.0 to 10.0 Hz
F6-04 Startup frequency active set time 0.3 0.3
0.0 to 100.0s
Set S-curve
F6-07 Acceleration/Deceleration mode 3 3
0: Linear acceleration/ deceleration
3: S-curve acceleration/ deceleration C
F6-08
Time proportion of S-curve at Accel
start
80.0 80.0
0.0% to Min. [(100.0% - F6-09), 80%]
F6-09 Time proportion of S-curve at Accel end 10.0 10.0
0.0% to Min. [(100.0% - F6-08), 80%]
F6-26
Time proportion of S-curve at Decel
start
20.0 20.0
0.0% to Min. [(100.0% - F6-27), 80%]
F6-27
Time proportion of S-curve at Decel
end
30.0 30.0
0.0% to Min. [(100.0% - F6-26), 80%]
F8-65 Brake apply keep frequency set time 0.50 0.50
0.00s to 10.00s
F8-66
Time proportion of S-curve at Stop
start
20.0 20.0
0.0% to Min. [(100.0% - F8-67), 80%]
F8-67
Time proportion of S-curve at Stop
start
30.0 30.0
0.0% to Min. [(100.0% - F8-66), 80%]
CONTINUE