248
4
4 Instructions4.6.4 Matrix Rotation and Shift
When M100 = ON, the binary oating-point number in D0 and D1 is converted based on the content
(exponential form) of D10 to D12.The result is stored in elements from head address D20.
Total number
of characters
Number of
characters in the
fractional part
Total number of characters
Number of characters
in the fractional part
1
12
4
D10
D11
D12
Exponential form
D1 D0
0.032745
3.2746E-02
2EH(.)
37H(7)
D20
D21
D22
b7-----b0
36H(6)
D23
33H(3)
32H(2)
34H(4)
b15-----b8
2DH(-)
32H(2)
D24
D25
00H
D26
45H(E)
30H(0)
20H (
space
) 20H (
space
)
EVAL: Conversion from string to binary oating-point number format
Overview
The EVAL instruction converts ASCII-encoded strings to binary oating-point numbers.
EVAL S D
Conversion from string to binary
oating-point number format
Applicable model:
H3U
S Operand
Start number of elements that store the string to be converted
to a binary oating-point number
32-bit instruction (9
steps)
DEVAL: Continuous
execution
DEVALP: Pulse
execution
D Result
Start number of elements that store the binary oating-point
number after conversion