6 Positioning and Interpolation DVIT: Interrupt positioning
7) Pulse output complete interrupts.
The "interrupt enabling ag bit" of special elements must be set. See the following table.
Y0 Y1 Y2 Y3 Y4 Attribute
M8352 M8372 M8392 M8412 M8432
Output complete
interrupt enabling
Y0 output
complete
interrupt
Y1 output
complete
interrupt
Y2 output
complete
interrupt
Y3 output
complete
interrupt
Y4 output
complete
interrupt
Corresponding
interrupt
8) The pulse output is stopped.
The pulse output can be stopped by setting the "pulse output stop ag bit" of special elements. See the
following table.
Y0 Y1 Y2 Y3 Y4 Attribute
M8349 M8369 M8389 M8409 M8429 Pulse output stop ag
Program example
This instruction is used to drive the system to accelerate from the 1000 Hz output frequency in the forward
direction at the speed segment to 5000 Hz after detecting an interrupt at the X3 rising edge, and output
50,000 pulses.