435
6
6 Positioning and Interpolation G90G01: 2-axis linear absolute position interpolation
1) Interpolation at the x- and y-axes (Y0/Y1) results in output complete interrupt of only one
pulse.
The "interrupt enabling ag bit" of special elements must be set. See the following table.
Y0 Y1 Y2 Y3 Y4 Attribute
M8352 M8372 M8392 M8412 M8432
Output complete interrupt
enabling
Y0 output
complete
interrupt
Y1 output
complete
interrupt
Y2 output
complete
interrupt
Y3 output
complete
interrupt
Y4 output
complete
interrupt
Corresponding interrupt
2) The pulse output is stopped.
The pulse output can be stopped by setting the "pulse output stop ag bit" of special elements. See the
following table.
Y0 Y1 Y2 Y3 Y4 Attribute
M8349 M8369 M8389 M8409 M8429 Pulse output stop ag