A.3 M8000 Flag and D8000 Register
710
Appendix
M
Element
Description
D
Element
Description
M8102 Reserved D8102
Customized version of customized software Fxxx, in
hexadecimal format
M8103 Reserved D8103
Customized iterative version of customized software
Fxxx, in hexadecimal format
M8104 Reserved D8104 Major version of FPGA software
M8105 Reserved D8105 Auxiliary version of FPGA software
M8106 Reserved D8106 Reserved
M8107 Reserved D8107 Reserved
M8108 Reserved D8108 Reserved
M8109 Reserved D8109 Reserved
COM0 communication link
M8110 Reserved D8110 Communication format, set on the UI, 0 by default
M8111 Reserved D8111
Communication station number, set on the UI, 1 by
default
M8112 Modbus - communication execution state D8112
Download and HMI monitoring protocols -
communication format setting
M8113 Modbus - communication error ag D8113 Reserved
M8114 Reserved D8114 Reserved
M8115 Reserved D8115 Reserved
M8116 Reserved D8116 Communication protocol, set on the UI, 0 by default
M8117 Reserved D8117 Reserved
M8118 Reserved D8118
Modbus - number of station with communication
errors
M8119 Timeout criterion D8119
Communication timeout criterion, set on the UI, 10
(100 ms) by default
COM1 communication link
M8120 Reserved D8120 Communication format, set on the UI, 0 by default
M8121 RS instruction - sending D8121
Communication station number, set on the UI, 1 by
default
M8122
Modbus - communication execution state
RS instruction - ag of sending
D8122
Download and HMI monitoring protocols -
communication format setting
RS instruction - volume of residual data transmitted
M8123
Modbus - communication error ag
RS instruction - ag of receipt
D8123 RS instruction - volume of received data
M8124 RS instruction - receiving D8124 RS instruction - STX
M8125 Reserved D8125 RS instruction - ETX
M8126 Reserved D8126 Communication protocol, set on the UI, 0 by default
M8127 Reserved D8127 PC link protocol - head data address required
M8128 Reserved D8128
Modbus - number of station with communication
errors
PC link protocol - volume of sent data required
M8129 Timeout criterion D8129
Communication timeout criterion, set on the UI, 10
(100 ms) by default
High-speed input instruction
M8130 HSZ instruction platform control mode D8130
Use of the HSZ high-speed comparison platform
(number recorded)
M8131 Used with M8130 D8131
Use of HSZ and PLSY speed models (number
recorded)
M8132 HSZ & PLSY speed modes D8132
Use of HSZ and PLSY speed model frequency
M8133 Used with M8132 D8133