- 131 -
Resvered
Factory default
value
F5-04
F5-09
Setup
range
F5-10
A01 output
selection
Factory default
value
9
F5-11
A02output
selection
Factory default
value
10
The standard output of analog output (zero offset is 0 and gain is 1) is 0mA to
20mA (or 0v TO 10V), and the output range of FMP is between 0Hz and
setup value of F5-09.
The corresponding value range that it indicates is shown in the table below
Set up value Function Range
0
Running
frequency
0 to maximum output frequency
1
Setup
frequency
0 to maximum output frequency
2 Output current 0 to 200% of the rated current of the motor
3 Output torque 0 to 200% of the rated torque of the motor
4 Output power 0 to 200% rated power
5 Output voltage 0 to 120% of the rated voltage of the driver
6
PULSE input
PULSE input
0.1kHz to 50.0kHz
7 AI1 0V to 10V
8 AI2 0V to 10V/0 to 20mA
9 AI3 0V to 10V
10
Feedback
frequency
0 to maximum frequency
11
Feedback
voltage
0 to maximum oil pressure
12~16 Reserved
Reserved
Factory default
value
F5-12
F5-13
Setup
range